We offer a versatile choice of little, medium as well as huge muffle furnaces appropriate for a range of industrial and also laboratory heat applications. In this article, we would like to review some key points of daily procedure and upkeep for muffle furnaces.
1. When the muffle furnace is made use of for the very first time or operated once more after it has actually been utilized for a long period of time, the heating system requires to be oven-dried: Open the heating system door at 20 ~ 200 ° C for 2-3h and after that close at 200 ~ 600 ° C for 2-3h.
2. Prior to the experiment, the temperature level controller should prevent resonance, and the positioning setting should not be also close to the electric furnace to avoid the digital components from working usually as a result of overheating. Shut off the power when moving the thermo controller.
3. Before use, readjust the controller to the called for operating temperature level, switch on the start code to power on the muffle furnace, after that the ammeter checks out, and also the gauged temperature level worth of the temperature level control table progressively increases, showing that the muffle heating system and the controller are working correctly.
4. muffle furnace and also the controller must work under a completely dry as well as the aerated environment, with ambient temperature level of 10-50 degrees Celsius, family member humidity less than 85%. There is no conductive dirt, explosive gas, or corrosive gases in the workplace. Where metallic products to be heated, a great deal of volatile and destructive gases will influence the surface area of the burner, leading to destruction as well as shortened life expectancy. It is not feasible to directly inject various liquids and molten steels right into the furnace as well as keep the within the furnace clean.
5. The temperature level of the heating system during usage shall not go beyond the maximum furnace temperature, nor might it help a very long time at the rated temperature. Burner life is reduced by utilizing at temperatures close to optimum. Do not leave the heating system at a high temperature when not required. The maximum temperature is shown on the furnace rating tag as well as on the back web page of this manual. During the experiment, the individual must not leave and take note of the temperature adjustment at any time. If abnormal problems are located, the power needs to be cut off immediately and revamped by specialist maintenance personnel.

We are muffle furnace manufacturers. If you are interested in our products, please feel free to contact us.

10 Procedure and Upkeep Guidelines for Muffle furnace(1)

  • Phone:+86 371 5502 7790
  • Fax: +86 371 5502 7790
  • E-mail: chengyi@chysk.com
  • Whatsapp/wechat: +86 156 3927 2359
  • Skype: jennyhao8819
  • Add: #136,10th Avenue,Jingnan 8th Road,Economic Development Zone,Zhengzhou,China
Follow Us
Newsletter

Enter your email to receive the latest information about Chengyi

Copyright © Henan Chengyi Equipment Science and Technology Co.,Ltd.
All Rights Reserved | Sitemap